RVTDocs.com
Namespace: Autodesk.Revit.DB

BuiltInFailures.RebarSystemFailures

Class
Description:
Failures related to rebar systems.
Inheritance Hierarchy:
System.Object
  Autodesk.Revit.DB.BuiltInFailures.RebarSystemFailures
Syntax
public static class RebarSystemFailures
BuiltInFailuresRebarSystemFailures Class Members:
Name Description
AreaReinforcementOutSideOfHost Area Reinforcement is sketched completely outside of its host.
AreaReinforcementRegenFail Can't regenerate Area Reinforcement.
AreaReinforcementsCollision Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
AreaReinforcementWrongHost Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
BarsTooCloseNumber Bars are too close together. Decrease the Number Of Lines parameter.
BarsTooCloseSpacing Bars are too close together. Increase the Maximum Spacing parameter.
BarsTooSparseSpacing Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
CannotPlaceAreaReinforcement Can't find a host for Area Reinforcement.
CannotPlaceAreaReinforcementWarn Can't find a host for Area Reinforcement.
CannotPlaceAreaReininforcement Can't find a host for Area Reinforcement.
CannotPlaceAreaReininforcementWarn Can't find a host for Area Reinforcement.
CannotPlacePathReinforcement Can't find a host for Path Reinforcement.
CannotPlacePathReinforcementWarn Can't find a host for Path Reinforcement.
CannotPlacePathReininforcement Can't find a host for Path Reinforcement.
CannotPlacePathReininforcementWarn Can't find a host for Path Reinforcement.
CannotUseAreaReinforcementHookTypeStyle At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
CannotUsePathReinforcementHookTypeStyle At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
DPartReinfDeletedEditDivision Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
DPartReinforcementDeleted Reinforcement hosted on highlighted Parts will be deleted.
HostFlagAreaOff
HostFlagAreaOn The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
HostFlagPathOff
HostFlagPathOn
InvalidLapSpliceInAreaReinforcement The instance major/minor lap lengths must be smaller than 1/2 of the overall length from the type in major and minor directions, respectively. The default values set for this parameters did not respect this criteria so they were automatically reset to the type values.
LessThanTwoBars Each reinforcement direction requires at least 2 bars. Please increase the number of bars.
PathReinforcementWrongHost Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
RebarSystemOffset Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
ThinHostFloor Rebar Cover Top and Bottom are too large for host.
ThinHostFloorError Rebar Cover Top and Bottom are too large for host.
ThinHostWall Rebar Cover Interior and Exterior are too large for host.
ThinHostWallError Rebar Cover Interior and Exterior are too large for host.