PanelScheduleView.SetSpareLoadValue
Method
Description:
Sets the value of the apparent load parameter for a spare
Sets the value of the apparent load parameter for a spare
Syntax
public void SetSpareLoadValue(
int row,
int column,
ElementId idLoadParameter,
double value
)
Parameters
Parameter | Type | Description |
---|---|---|
row | Int32 | A row where the valid spare is |
column | Int32 | A column where the valid spare is |
idLoadParameter | ElementId | One of 4 valid load parameters: RBS_ELEC_APPARENT_LOAD, RBS_ELEC_APPARENT_LOAD_PHASEA, RBS_ELEC_APPARENT_LOAD_PHASEB, RBS_ELEC_APPARENT_LOAD_PHASEC |
value | Double | The value of the spare's load for the given parameter |
Return Value
Exceptions
Exception | Condition |
---|---|
ArgumentException | The load parameter id is not valid. |
ArgumentNullException | A non-optional argument was null |
ArgumentOutOfRangeException | The given value for value must be non-negative. |
ArgumentsInconsistentException | The row column combination does not represent a valid spare. |