RVTDocs.com

CircuitNamingScheme.IsValidCombinedParameters

Method
Description:
Validates whether the combined parameters is valid.
Remarks:

Currently the following parameters are supported:

  • Shared Parameters
  • RBS_ELEC_CIRCUIT_NAME
  • RBS_ELEC_CIRCUIT_PANEL_PARAM
  • RBS_ELEC_CIRCUIT_TYPE
  • CIRCUIT_LOAD_CLASSIFICATION_ABBREVIATION_PARAM
  • RBS_ELEC_CIRCUIT_NAMING_INDEX
  • RBS_ELEC_NUMBER_OF_POLES
  • RBS_ELEC_CIRCUIT_RATING_PARAM
  • RBS_ELEC_CIRCUIT_FRAME_PARAM
  • RBS_ELEC_VOLTAGE
  • CIRCUIT_PHASE_PARAM
  • CIRCUIT_WAYS_PARAM
  • RBS_ELEC_CIRCUIT_SLOT_INDEX
Syntax
Parameters
Parameter Type Description
aDocument Document The document.
data IList The array of TableCellCombinedParameterData to be set as combined parameters.
Return Value
Type Description
Boolean Returns true if the combined parameters are valid, and false otherwise.
Exceptions
Exception Condition
ArgumentNullException A non-optional argument was null