RVTDocs.com
Namespace: Autodesk.Revit.DB Class: Ceiling

Ceiling.Create(Document, IList<CurveLoop>, ElementId, ElementId)

Method
Description:
Creates a new instance of ceiling within the project.
Remarks:
To validate curve loop profile use BoundaryValidation.
Syntax
public static Ceiling Create(
	Document document,
	IList<CurveLoop> curveLoops,
	ElementId ceilingTypeId,
	ElementId levelId
)
Examples
Ceiling CreateCeilingAtElevation(Document document, Level level, double elevation)
{
   XYZ first = new XYZ(0, 0, 0);
   XYZ second = new XYZ(20, 0, 0);
   XYZ third = new XYZ(20, 15, 0);
   XYZ fourth = new XYZ(0, 15, 0);
   CurveLoop profile = new CurveLoop();
   profile.Append(Line.CreateBound(first, second));
   profile.Append(Line.CreateBound(second, third));
   profile.Append(Line.CreateBound(third, fourth));
   profile.Append(Line.CreateBound(fourth, first));

   var ceiling = Ceiling.Create(document, new List<CurveLoop> { profile }, ElementId.InvalidElementId, level.Id);
   Parameter param = ceiling.get_Parameter(BuiltInParameter.CEILING_HEIGHTABOVELEVEL_PARAM);
   param.Set(elevation);

   return ceiling;
}
Parameters
Parameter Type Description
document Document The document in which the new ceiling is created.
curveLoops IList An array of planar curve loops that represent the profile of the ceiling.
ceilingTypeId ElementId Id of the ceiling type to be used by the new ceiling. If InvalidElementId is passed, the default type will be used.
levelId ElementId Id of the level on which the ceiling is to be placed.
Return Value
Type Description
Ceiling If successful a new ceiling object within the project.
Exceptions
Exception Condition
ArgumentException The ElementId levelId is not a Level. -or- The ElementId ceilingTypeId does not correspond to a CeilingType. -or- The input curve loops cannot compose a valid boundary, that means: the "curveLoops" collection is empty; or some curve loops intersect with each other; or each curve loop is not closed individually; or each curve loop is not planar; or each curve loop is not in a plane parallel to the horizontal(XY) plane; or input curves contain at least one helical curve. -or- Input curves build invalid sketch. -or- Failed to create curve elements.
ArgumentNullException A non-optional argument was null
InvalidOperationException Cannot generate a sketch. -or- Failed to create new element.
ModificationForbiddenException The document is in failure mode: an operation has failed, and Revit requires the user to either cancel the operation or fix the problem (usually by deleting certain elements). -or- The document is being loaded, or is in the midst of another sensitive process.
ModificationOutsideTransactionException The document has no open transaction.