AnalyticalPowerDistributableNodeData.GetAllAvailableConnectedPhasesOnDownstream
Method
Description:
Get all the available electrical connected phases that this power distributable node can provide to the downstream node.
Get all the available electrical connected phases that this power distributable node can provide to the downstream node.
Remarks:
If node B supplies from node A, node B is the downstream node of node A, and node A is the upstream node of node B. Usually one node may have many downstream nodes, but TransferSwitch can only have one downstream node.
If node B supplies from node A, node B is the downstream node of node A, and node A is the upstream node of node B. Usually one node may have many downstream nodes, but TransferSwitch can only have one downstream node.
Syntax
Parameters
Parameter | Type | Description |
---|---|---|
id | ElementId | The downstream node id. |
Return Value
Type | Description |
---|---|
IList | All the available electrical connected phases that this power distributable node can provide to the downstream node. |
Exceptions
Exception | Condition |
---|---|
ArgumentException | The id isn't a downstream node id of the power distributable node. |
ArgumentNullException | A non-optional argument was null |